StacksVerified U.S. regulatory reference

40 CFR Part 98, Table W-5

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov

Industry segment | Source type/component | Emissionfactor(scf methane/hour/component)

Population Emission Factors—LNG Storage Compressor, Gas Service

LNG storageVapor Recovery Compressor 14.17
LNG import and export equipment

Population Emission Factors—Below Grade Transmission-Distribution Transfer Station Components and Below Grade Metering-Regulating Station 2 Components, Gas Service 3

Natural gas distributionBelow Grade T-D Transfer Station0.3
Below Grade M&R Station0.3

Population Emission Factors—Distribution Mains, Gas Service 4

Natural gas distributionUnprotected Steel5.1
Protected Steel0.57
Plastic0.17
Cast Iron6.9

Population Emission Factors—Distribution Services, Gas Service 5

Natural gas distributionUnprotected Steel0.086
Protected Steel0.0077
Plastic0.0016
Copper0.03

Population Emission Factors—Interconnect, Direct Sale, or Farm Tap Stations 2 3

Onshore natural gas transmission pipelineTransmission Company Interconnect M&R Station166
Direct Sale or Farm Tap Station1.3

Population Emission Factors—Transmission Pipelines, Gas Service 4

Onshore natural gas transmission pipelineUnprotected Steel0.74
Protected Steel0.041
Plastic0.061
Cast Iron27

1 Emission Factor is in units of “scf methane/hour/compressor.”

2 Excluding customer meters.

3 Emission Factor is in units of “scf methane/hour/station.”

4 Emission Factor is in units of “scf methane/hour/mile.”

5 Emission Factor is in units of “scf methane/hour/number of services.”

[89 FR 42326, May 14, 2024]